# Arsenic and nickel calculator (AAS / ICP on the filter digest) in ng/m³ | NovaLIMS

> Free arsenic and nickel calculator by the AAS / ICP on the filter digest method (EPA IO-3.4). Enter your readings to get arsenic and nickel in PM10 in ng/m³, with the formula, a worked example and typo checks.

Source: https://novalims.in/tools/calculators/arsenic-nickel-ambient

## How arsenic and nickel is calculated

Free arsenic and nickel calculator (AAS / ICP on the filter digest method), following EPA IO-3.4. Enter 7 readings to get arsenic and nickel in PM10 in ng/m³, with the formula filled in step by step.

1.  ### Volume of air sampled · m³
    
    `V = Q × t`
    
2.  ### Arsenic and nickel in PM10 · ng/m³
    
    `C = (Mₛ − M_b) × Vₛ × Fₐ × 1000 / (V × Fₜ)`
    

## What you need

| Symbol | Reading | Unit | Notes |
| --- | --- | --- | --- |
| Q | Sampling rate | m³/min | usually 0.5–2 m³/min |
| t | Sampling time | min | usually 60–1440 min |
| Mₛ | Concentration in the sample digest | µg/ml | usually 0–10 µg/ml |
| M_b | Concentration in the blank digest | µg/ml | usually 0–1 µg/ml |
| Vₛ | Total volume of extract | ml | usually 5–100 ml |
| Fₐ | Total exposed area of the filter | cm² | usually 10–600 cm² |
| Fₜ | Area of filter taken for digestion | cm² | usually 1–600 cm² |

## Worked example

Readings:

-   Sampling rate: **Q = 1.1 m³/min**
-   Sampling time: **t = 1440 min**
-   Concentration in the sample digest: **Mₛ = 0.042 µg/ml**
-   Concentration in the blank digest: **M\_b = 0.004 µg/ml**
-   Total volume of extract: **Vₛ = 25 ml**
-   Total exposed area of the filter: **Fₐ = 406 cm²**
-   Area of filter taken for digestion: **Fₜ = 50.8 cm²**

1.  ### Volume of air sampled
    
    `V = 1.1 × 1440 = 1,584.0 m³`
    
2.  ### Arsenic and nickel in PM10
    
    `C = (0.042 − 0.004) × 25 × 406 × 1000 / (1,584.0 × 50.8) = 4.793 ng/m³`
    

Result: Arsenic and nickel in PM10 **4.793 ng/m³**.

## Checks and units

-   The sample digest reads lower than the blank.

## Questions

### How do you calculate arsenic and nickel by the AAS / ICP on the filter digest method?

Work through 2 steps in order. Volume of air sampled: V = Q × t. Arsenic and nickel in PM10: C = (Mₛ − M\_b) × Vₛ × Fₐ × 1000 / (V × Fₜ). Here Q is the sampling rate (m³/min), t is the sampling time (min), Mₛ is the concentration in the sample digest (µg/ml), M\_b is the concentration in the blank digest (µg/ml), Vₛ is the total volume of extract (ml), Fₐ is the total exposed area of the filter (cm²), Fₜ is the area of filter taken for digestion (cm²). The result is in ng/m³.

### What unit is arsenic and nickel reported in?

Arsenic and nickel in PM10 is reported in ng/m³, to 3 decimal places.

### Which standard does this arsenic and nickel calculation follow?

It follows the calculation in EPA IO-3.4. Check it against the current edition of the standard and your lab’s SOP before reporting.

### Can you show a worked example?

With sampling rate = 1.1 m³/min, sampling time = 1440 min, concentration in the sample digest = 0.042 µg/ml, concentration in the blank digest = 0.004 µg/ml, total volume of extract = 25 ml, total exposed area of the filter = 406 cm², area of filter taken for digestion = 50.8 cm², the result is arsenic and nickel in PM10 = 4.793 ng/m³.

### What mistakes should I look out for?

The sample digest reads lower than the blank.

### Is this arsenic and nickel calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

## Related calculators

-   [Benzo(a)pyrene (Solvent extraction and GC): Metals & organics](https://novalims.in/tools/calculators/bap-ambient)
-   [Lead (AAS / ICP on the filter digest): Metals & organics](https://novalims.in/tools/calculators/lead-ambient)

[All ambient air calculators →](https://novalims.in/tools/calculators/ambient-air)

Last reviewed 10 November 2026. Version 1. Follows EPA IO-3.4. [How we check our formulas](https://novalims.in/tools/calculators/methodology)

Check results against your own method and SOP before reporting. Found an error? [Tell us](mailto:hello@novalims.in?subject=Calculator%20check) and we’ll check it.

## Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.

[Book a Demo](https://novalims.in/contact) [Start Free Trial](https://novalims.in/contact?intent=trial)