# Emission per kWh calculator – Calculation (DG sets) | NovaLIMS

> Free emission per kWh calculator by the calculation (DG sets) method (CPCB DG set norms). Enter your readings to get emission in g/kWh, with the formula, a worked example and typo checks.

Source: https://novalims.in/tools/calculators/emission-factor

## How emission per kWh is calculated

Free emission per kWh calculator (calculation (DG sets) method), following CPCB DG set norms. Enter 3 readings to get emission in g/kWh, with the formula filled in step by step.

1.  ### Emission · g/kWh
    
    `EF = C × Q / (1000 × P)`
    

## What you need

| Symbol | Reading | Unit | Notes |
| --- | --- | --- | --- |
| C | Concentration | mg/Nm³ | usually 0–5000 mg/Nm³ |
| Q | Flow rate | Nm³/h | usually 1–100000 Nm³/h |
| P | Power output | kW | usually 1–10000 kW |

## Worked example

Readings:

-   Concentration: **C = 48.5 mg/Nm³**
-   Flow rate: **Q = 1850 Nm³/h**
-   Power output: **P = 320 kW**

1.  ### Emission
    
    `EF = 48.5 × 1850 / (1000 × 320) = 0.280 g/kWh`
    

Result: Emission **0.280 g/kWh**.

## Questions

### How do you calculate emission per kWh by the calculation (DG sets) method?

Emission = C × Q / (1000 × P). Here C is the concentration (mg/Nm³), Q is the flow rate (Nm³/h), P is the power output (kW). The result is in g/kWh.

### What unit is emission per kWh reported in?

Emission is reported in g/kWh, to 3 decimal places.

### Which standard does this emission per kWh calculation follow?

It follows the calculation in CPCB DG set norms. Check it against the current edition of the standard and your lab’s SOP before reporting.

### Can you show a worked example?

With concentration = 48.5 mg/Nm³, flow rate = 1850 Nm³/h, power output = 320 kW, the result is emission = 0.280 g/kWh.

### Is this emission per kWh calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

## Related calculators

-   [Emission rate (Calculation): Flow & emission rate](https://novalims.in/tools/calculators/emission-rate)
-   [Stack gas flow rate (Pitot tube): Flow & emission rate](https://novalims.in/tools/calculators/stack-flow-rate)

[All stack emissions calculators →](https://novalims.in/tools/calculators/stack)

Last reviewed 10 November 2026. Version 1. Follows CPCB DG set norms. [How we check our formulas](https://novalims.in/tools/calculators/methodology)

Check results against your own method and SOP before reporting. Found an error? [Tell us](mailto:hello@novalims.in?subject=Calculator%20check) and we’ll check it.

## Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.

[Book a Demo](https://novalims.in/contact) [Start Free Trial](https://novalims.in/contact?intent=trial)