# Illumination calculator (Lux meter, grid of points) in lux | NovaLIMS

> Free illumination calculator by the lux meter, grid of points method (IS 3646 (Part 1)). Enter your readings to get average illuminance in lux, with the formula, a worked example and typo checks.

Source: https://novalims.in/tools/calculators/illumination

## How illumination is calculated

Free illumination calculator (lux meter, grid of points method), following IS 3646 (Part 1). Enter 1 reading to get average illuminance in lux, with the formula filled in step by step.

1.  ### Average illuminance · lux
    
    `Eavg = avg(E)`
    
2.  ### Lowest · lux
    
    `Emin = min(E)`
    
3.  ### Highest · lux
    
    `Emax = max(E)`
    
4.  ### Uniformity (lowest ÷ average)
    
    `U = min(E) / avg(E)`
    

## What you need

| Symbol | Reading | Unit | Notes |
| --- | --- | --- | --- |
| E | Illuminance | lux | one per point; usually 1–100000 lux |

## Worked example

Readings:

-   Illuminance: **E = 410, 385, 402, 356, 448, 421, 390, 372, 415 lux**

1.  ### Average illuminance
    
    `Eavg = avg(410, 385, 402, 356, 448, 421, 390, 372, 415) = 400 lux`
    
2.  ### Lowest
    
    `Emin = min(410, 385, 402, 356, 448, 421, 390, 372, 415) = 356 lux`
    
3.  ### Highest
    
    `Emax = max(410, 385, 402, 356, 448, 421, 390, 372, 415) = 448 lux`
    
4.  ### Uniformity (lowest ÷ average)
    
    `U = min(410, 385, 402, 356, 448, 421, 390, 372, 415) / avg(410, 385, 402, 356, 448, 421, 390, 372, 415) = 0.89`
    

Result: Average illuminance **400 lux**; lowest **356 lux**; highest **448 lux**; uniformity (lowest ÷ average) **0.89**.

## Checks and units

-   **Typical values:** Offices: about 300–500 lux

## Questions

### How do you calculate illumination by the lux meter, grid of points method?

Work through 4 steps in order. Average illuminance: Eavg = avg(E). Lowest: Emin = min(E). Highest: Emax = max(E). Uniformity (lowest ÷ average): U = min(E) / avg(E). The result is in lux.

### What unit is illumination reported in?

Average illuminance is reported in lux, to 0 decimal places.

### Which standard does this illumination calculation follow?

It follows the calculation in IS 3646 (Part 1). Check it against the current edition of the standard and your lab’s SOP before reporting.

### Can you show a worked example?

With illuminance = 410, 385, 402, 356, 448, 421, 390, 372, 415 lux, the result is average illuminance = 400 lux and lowest = 356 lux and highest = 448 lux and uniformity (lowest ÷ average) = 0.89.

### What is a typical illumination value?

Offices: about 300–500 lux

### Is this illumination calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Last reviewed 10 November 2026. Version 1. Follows IS 3646 (Part 1). [How we check our formulas](https://novalims.in/tools/calculators/methodology)

Check results against your own method and SOP before reporting. Found an error? [Tell us](mailto:hello@novalims.in?subject=Calculator%20check) and we’ll check it.

## Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.

[Book a Demo](https://novalims.in/contact) [Start Free Trial](https://novalims.in/contact?intent=trial)