# Equivalent noise level (Leq) calculator (Energy average of readings) in dB(A) | NovaLIMS

> Free equivalent noise level (Leq) calculator by the energy average of readings method (IS 9989). Enter your readings to get equivalent continuous level in dB(A), with the formula, a worked example and typo checks.

Source: https://novalims.in/tools/calculators/noise-leq

## How equivalent noise level (Leq) is calculated

Free equivalent noise level (Leq) calculator (energy average of readings method), following IS 9989. Enter 1 reading to get equivalent continuous level in dB(A), with the formula filled in step by step.

1.  ### Relative sound energy · for each reading
    
    `E = 10 ^ (L / 10)`
    
2.  ### Equivalent continuous level · dB(A)
    
    `Leq = 10 × log10(avg(E))`
    
3.  ### Lowest reading · dB(A)
    
    `Lmin = min(L)`
    
4.  ### Highest reading · dB(A)
    
    `Lmax = max(L)`
    

## What you need

| Symbol | Reading | Unit | Notes |
| --- | --- | --- | --- |
| L | Sound level | dB(A) | one per reading; usually 20–140 dB(A) |

## Worked example

Readings:

-   Sound level: **L = 58.2, 61.5, 63, 59.8, 66.4, 60.1 dB(A)**

1.  ### Relative sound energy
    
    `E = 6,60,693, 14,12,538, 19,95,262, 9,54,993, 43,65,158, 10,23,293`
    
2.  ### Equivalent continuous level
    
    `Leq = 10 × log10(avg(6,60,693, 14,12,538, 19,95,262, 9,54,993, 43,65,158, 10,23,293)) = 62.4 dB(A)`
    
3.  ### Lowest reading
    
    `Lmin = min(58.2, 61.5, 63, 59.8, 66.4, 60.1) = 58.2 dB(A)`
    
4.  ### Highest reading
    
    `Lmax = max(58.2, 61.5, 63, 59.8, 66.4, 60.1) = 66.4 dB(A)`
    

Result: Equivalent continuous level **62.4 dB(A)**; lowest reading **58.2 dB(A)**; highest reading **66.4 dB(A)**.

## Checks and units

-   **Typical values:** Residential area: 55 dB(A) day, 45 dB(A) night

## Questions

### How do you calculate equivalent noise level (Leq) by the energy average of readings method?

Work through 4 steps in order. Relative sound energy: E = 10 ^ (L / 10). Equivalent continuous level: Leq = 10 × log10(avg(E)). Lowest reading: Lmin = min(L). Highest reading: Lmax = max(L). The result is in dB(A).

### What unit is equivalent noise level (Leq) reported in?

Equivalent continuous level is reported in dB(A), to 1 decimal place.

### Which standard does this equivalent noise level (Leq) calculation follow?

It follows the calculation in IS 9989. Check it against the current edition of the standard and your lab’s SOP before reporting.

### Can you show a worked example?

With sound level = 58.2, 61.5, 63, 59.8, 66.4, 60.1 dB(A), the result is equivalent continuous level = 62.4 dB(A) and lowest reading = 58.2 dB(A) and highest reading = 66.4 dB(A).

### What is a typical equivalent noise level (Leq) value?

Residential area: 55 dB(A) day, 45 dB(A) night

### Is this equivalent noise level (Leq) calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

## Related calculators

-   [DG set insertion loss (Inside and outside the enclosure): Noise](https://novalims.in/tools/calculators/dg-insertion-loss)
-   [Day-night noise level (Ldn) (Calculation): Noise](https://novalims.in/tools/calculators/noise-ldn)

[All noise & illumination calculators →](https://novalims.in/tools/calculators/noise-light)

Last reviewed 10 November 2026. Version 1. Follows IS 9989. [How we check our formulas](https://novalims.in/tools/calculators/methodology)

Check results against your own method and SOP before reporting. Found an error? [Tell us](mailto:hello@novalims.in?subject=Calculator%20check) and we’ll check it.

## Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.

[Book a Demo](https://novalims.in/contact) [Start Free Trial](https://novalims.in/contact?intent=trial)