Skip to content
100%PM10

PM10 (indoor)

GravimetricResult in µg/m³IS 5182ASHRAE

Dust collected on a filter, weighed

Formulas, in order
Average flow rate · L/min
Q =(F₁+F₂)2
Volume of air sampled · m³
V =Q×T1000
PM10 · µg/m³
PM =(W2−W1)×1000000V

Your readings

5 of 5 filled

Example values shown.

L/min
L/min
min
g
g
PM10Calculated live as you type
343.4 µg/m³µg/m³
Worked out with the formula above.

Calculations you finish this week are counted here, on this device only.

How PM10 (indoor) is calculated

Free PM10 (indoor) calculator (gravimetric method), following IS 5182, ASHRAE. Enter 5 readings to get PM10 in µg/m³, with the formula filled in step by step.

  1. Average flow rate · L/min

    Q = (F₁ + F₂) / 2

  2. Volume of air sampled · m³

    V = Q × T / 1000

  3. PM10 · µg/m³

    PM = (W2 − W1) × 1000000 / V

What you need

SymbolReadingUnitNotes
F₁Initial flow rateL/minusually 0.5–50 L/min
F₂Final flow rateL/minusually 0.5–50 L/min
TSampling timeminusually 10–1440 min
W1Initial weight of filtergusually 0–5 g
W2Final weight of filtergusually 0–5 g

Worked example

Readings:

  • Initial flow rate: F₁ = 16.7 L/min
  • Final flow rate: F₂ = 16.3 L/min
  • Sampling time: T = 480 min
  • Initial weight of filter: W1 = 0.1421 g
  • Final weight of filter: W2 = 0.14482 g
  1. Average flow rate

    Q = (16.7 + 16.3) / 2 = 16.50 L/min

  2. Volume of air sampled

    V = 16.50 × 480 / 1000 = 7.920 m³

  3. PM10

    PM = (0.14482 − 0.1421) × 1000000 / 7.920 = 343.4 µg/m³

Result: PM10 343.4 µg/m³.

Checks and units

  • The final filter weight is lower than the initial weight.

Questions

How do you calculate PM10 (indoor) by the gravimetric method?

Work through 3 steps in order. Average flow rate: Q = (F₁ + F₂) / 2. Volume of air sampled: V = Q × T / 1000. PM10: PM = (W2 − W1) × 1000000 / V. Here F₁ is the initial flow rate (L/min), F₂ is the final flow rate (L/min), T is the sampling time (min), W1 is the initial weight of filter (g), W2 is the final weight of filter (g). The result is in µg/m³.

What unit is PM10 (indoor) reported in?

PM10 is reported in µg/m³, to 1 decimal place.

Which standard does this PM10 (indoor) calculation follow?

It follows the calculation in IS 5182, ASHRAE. Check it against the current edition of the standard and your lab’s SOP before reporting.

Can you show a worked example?

With initial flow rate = 16.7 L/min, final flow rate = 16.3 L/min, sampling time = 480 min, initial weight of filter = 0.1421 g, final weight of filter = 0.14482 g, the result is PM10 = 343.4 µg/m³.

What mistakes should I look out for?

The final filter weight is lower than the initial weight.

Is this PM10 (indoor) calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Related calculators

All indoor air calculators →

Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.

Run every calculation inside your LIMS