Skip to content
Q

Stack gas flow rate

Pitot tubeResult in Nm³/hIS 11255 (Part 3)

Pitot tube velocity across the stack

Formula
Q =3600×Ar×Av×(TaTs)

Your readings

4 of 4 filled

Example values shown.

m/s
m²
K
K
Flow rateCalculated live as you type
6,164 Nm³/hNm³/h
Worked out with the formula above.

Calculations you finish this week are counted here, on this device only.

How stack gas flow rate is calculated

Free stack gas flow rate calculator (pitot tube method), following IS 11255 (Part 3). Enter 4 readings to get flow rate in Nm³/h, with the formula filled in step by step.

  1. Flow rate · Nm³/h

    Q = 3600 × Ar × Av × (Ta / Ts)

What you need

SymbolReadingUnitNotes
AvAverage velocity of stack gasm/susually 0.5–40 m/s
ArCross-sectional area of the stackm²usually 0.01–50 m²
TaNormal temperature (absolute)Kusually 273–303 K
TsStack gas temperature (absolute)Kusually 273–900 K

Worked example

Readings:

  • Average velocity of stack gas: Av = 12.4 m/s
  • Cross-sectional area of the stack: Ar = 0.196 m²
  • Normal temperature (absolute): Ta = 298 K
  • Stack gas temperature (absolute): Ts = 423 K
  1. Flow rate

    Q = 3600 × 0.196 × 12.4 × (298 / 423) = 6,164 Nm³/h

Result: Flow rate 6,164 Nm³/h.

Questions

How do you calculate stack gas flow rate by the pitot tube method?

Flow rate = 3600 × Ar × Av × (Ta / Ts). Here Av is the average velocity of stack gas (m/s), Ar is the Cross-sectional area of the stack (m²), Ta is the normal temperature (absolute) (K), Ts is the stack gas temperature (absolute) (K). The result is in Nm³/h.

What unit is stack gas flow rate reported in?

Flow rate is reported in Nm³/h, to 0 decimal places.

Which standard does this stack gas flow rate calculation follow?

It follows the calculation in IS 11255 (Part 3). Check it against the current edition of the standard and your lab’s SOP before reporting.

Can you show a worked example?

With average velocity of stack gas = 12.4 m/s, Cross-sectional area of the stack = 0.196 m², normal temperature (absolute) = 298 K, stack gas temperature (absolute) = 423 K, the result is flow rate = 6,164 Nm³/h.

Is this stack gas flow rate calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Related calculators

All stack emissions calculators →

Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.

Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.