How benzo(a)pyrene is calculated
Free benzo(a)pyrene calculator (solvent extraction and GC method), following IS 5182 (Part 12). Enter 5 readings to get benzo(a)pyrene in ng/m³, with the formula filled in step by step.
Volume of air sampled · m³
Vs = Q × T
Benzo(a)pyrene · ng/m³
BaP = Cₛ × Vₑ / (Vᵢ × Vs)
What you need
| Symbol | Reading | Unit | Notes |
|---|---|---|---|
| Q | Average flow rate | m³/min | usually 0.5–2 m³/min |
| T | Sampling time | min | usually 60–1440 min |
| Cₛ | BaP in the extract (from the GC) | ng/µl | usually 0–10 ng/µl |
| Vₑ | Final volume of extract | µl | usually 100–5000 µl |
| Vᵢ | Injection volume | µl | usually 0.5–10 µl |
Worked example
Readings:
- Average flow rate: Q = 1.1 m³/min
- Sampling time: T = 1440 min
- BaP in the extract (from the GC): Cₛ = 0.85 ng/µl
- Final volume of extract: Vₑ = 1000 µl
- Injection volume: Vᵢ = 1 µl
Volume of air sampled
Vs = 1.1 × 1440 = 1,584.0 m³
Benzo(a)pyrene
BaP = 0.85 × 1000 / (1 × 1,584.0) = 0.537 ng/m³
Result: Benzo(a)pyrene 0.537 ng/m³.
Checks and units
- Typical values: Annual standard (NAAQS): 1 ng/m³
Questions
How do you calculate benzo(a)pyrene by the solvent extraction and GC method?
Work through 2 steps in order. Volume of air sampled: Vs = Q × T. Benzo(a)pyrene: BaP = Cₛ × Vₑ / (Vᵢ × Vs). Here Q is the average flow rate (m³/min), T is the sampling time (min), Cₛ is the BaP in the extract (from the GC) (ng/µl), Vₑ is the final volume of extract (µl), Vᵢ is the injection volume (µl). The result is in ng/m³.
What unit is benzo(a)pyrene reported in?
Benzo(a)pyrene is reported in ng/m³, to 3 decimal places.
Which standard does this benzo(a)pyrene calculation follow?
It follows the calculation in IS 5182 (Part 12). Check it against the current edition of the standard and your lab’s SOP before reporting.
Can you show a worked example?
With average flow rate = 1.1 m³/min, sampling time = 1440 min, BaP in the extract (from the GC) = 0.85 ng/µl, final volume of extract = 1000 µl, injection volume = 1 µl, the result is benzo(a)pyrene = 0.537 ng/m³.
What is a typical benzo(a)pyrene value?
Annual standard (NAAQS): 1 ng/m³
Is this benzo(a)pyrene calculator free?
Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.
Related calculators