Skip to content
CO

Carbon monoxide (stack)

Analyser (ppm to mg/m³ and g/kWh)Result in mg/m³IS 11255CPCB DG set norms

Flue gas analyser reading in ppm

Formulas, in order
Carbon monoxide (stack) · mg/m³
mg =ppm×28.0124.45
Carbon monoxide (stack) · g/kWh
gkwh =0.003591×ppm

Your readings

1 of 1 filled

Example values shown.

ppm
Molecular weight of COConstant · fixed by the method28.01🔒
Molar volume at 25 °C and 1 atmConstant · fixed by the method24.45L
g/kWh per ppmConstant · fixed by the method0.003591🔒
Carbon monoxide (stack)Calculated live as you type
481.15 mg/m³mg/m³
  • Carbon monoxide (stack)1.508 g/kWh
Worked out with the formula above.

Calculations you finish this week are counted here, on this device only.

How carbon monoxide (stack) is calculated

Free carbon monoxide (stack) calculator (analyser (ppm to mg/m³ and g/kWh) method), following IS 11255, CPCB DG set norms. Enter 1 reading to get carbon monoxide (stack) in mg/m³, with the formula filled in step by step.

  1. Carbon monoxide (stack) · mg/m³

    mg = ppm × 28.01 / 24.45

  2. Carbon monoxide (stack) · g/kWh

    gkwh = 0.003591 × ppm

What you need

SymbolReadingUnitNotes
ppmCO readingppmusually 0–5000 ppm

Fixed values in the formula

SymbolConstantValue
28.01Molecular weight of CO28.01
24.45Molar volume at 25 °C and 1 atm24.45 L
0.003591g/kWh per ppm0.003591

Worked example

Readings:

  • CO reading: ppm = 420 ppm
  1. Carbon monoxide (stack)

    mg = 420 × 28.01 / 24.45 = 481.15 mg/m³

  2. Carbon monoxide (stack)

    gkwh = 0.003591 × 420 = 1.508 g/kWh

Result: Carbon monoxide (stack) 481.15 mg/m³; carbon monoxide (stack) 1.508 g/kWh.

Questions

How do you calculate carbon monoxide (stack) by the analyser (ppm to mg/m³ and g/kWh) method?

Work through 2 steps in order. Carbon monoxide (stack): mg = ppm × 28.01 / 24.45. Carbon monoxide (stack): gkwh = 0.003591 × ppm. Here ppm is the CO reading (ppm). The result is in mg/m³.

What unit is carbon monoxide (stack) reported in?

Carbon monoxide (stack) is reported in mg/m³, to 2 decimal places.

Which standard does this carbon monoxide (stack) calculation follow?

It follows the calculation in IS 11255, CPCB DG set norms. Check it against the current edition of the standard and your lab’s SOP before reporting.

Can you show a worked example?

With CO reading = 420 ppm, the result is carbon monoxide (stack) = 481.15 mg/m³ and carbon monoxide (stack) = 1.508 g/kWh.

Is this carbon monoxide (stack) calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Related calculators

All stack emissions calculators →

Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.

Run every calculation inside your LIMS