How sulphur dioxide (stack) is calculated
Free sulphur dioxide (stack) calculator (barium perchlorate titration method), following IS 11255 (Part 2). Enter 10 readings to get sulphur dioxide (stack) in mg/Nm³, with the formula filled in step by step.
Volume of gas sampled (meter) · m³
V = T × Q / 1000
Absolute meter pressure · mmHg
P = Pa − Pv
Volume at normal conditions · Nm³
VN = V × 298 × P / (Tm × 760)
Sulphur dioxide (stack) · mg/Nm³
C = 0.032 × (Vₛ − V_b) × N × (Vₛₒₗ / Vₐ) × 1000 / VN
Sulphur dioxide (stack) · ppm
ppm = C × 24.45 / 64.066
What you need
| Symbol | Reading | Unit | Notes |
|---|---|---|---|
| T | Sampling time | min | usually 5–240 min |
| Q | Flow rate | L/min | usually 0.1–10 L/min |
| Tm | Average dry gas meter temperature (absolute) | K | usually 273–330 K |
| Pa | Atmospheric pressure | mmHg | usually 600–800 mmHg |
| Pv | Vacuum at the meter | mmHg | usually 0–200 mmHg |
| Vₛ | Barium perchlorate used for sample | ml | usually 0–50 ml |
| V_b | Barium perchlorate used for blank | ml | usually 0–2 ml |
| N | Normality of barium perchlorate | N | usually 0.001–0.1 N |
| Vₛₒₗ | Total volume of absorbing solution | ml | usually 10–500 ml |
| Vₐ | Aliquot titrated | ml | usually 1–100 ml |
Fixed values in the formula
| Symbol | Constant | Value |
|---|---|---|
| 0.032 | Milliequivalent weight of SO₂ | 0.032 g/meq |
| 64.066 | Molecular weight of SO₂ | 64.066 |
| 24.45 | Molar volume at 25 °C and 1 atm | 24.45 L |
Worked example
Readings:
- Sampling time: T = 60 min
- Flow rate: Q = 1 L/min
- Average dry gas meter temperature (absolute): Tm = 303 K
- Atmospheric pressure: Pa = 712 mmHg
- Vacuum at the meter: Pv = 25 mmHg
- Barium perchlorate used for sample: Vₛ = 4.6 ml
- Barium perchlorate used for blank: V_b = 0.1 ml
- Normality of barium perchlorate: N = 0.01 N
- Total volume of absorbing solution: Vₛₒₗ = 100 ml
- Aliquot titrated: Vₐ = 20 ml
Volume of gas sampled (meter)
V = 60 × 1 / 1000 = 0.0600 m³
Absolute meter pressure
P = 712 − 25 = 687.0 mmHg
Volume at normal conditions
VN = 0.0600 × 298 × 687.0 / (303 × 760) = 0.0533 Nm³
Sulphur dioxide (stack)
C = 0.032 × (4.6 − 0.1) × 0.01 × (100 / 20) × 1000 / 0.0533 = 135.0 mg/Nm³
Sulphur dioxide (stack)
ppm = 135.0 × 24.45 / 64.066 = 51.5 ppm
Result: Sulphur dioxide (stack) 135.0 mg/Nm³; sulphur dioxide (stack) 51.5 ppm.
Checks and units
- The sample titre is less than the blank, so the result would be negative.
Questions
How do you calculate sulphur dioxide (stack) by the barium perchlorate titration method?
Work through 5 steps in order. Volume of gas sampled (meter): V = T × Q / 1000. Absolute meter pressure: P = Pa − Pv. Volume at normal conditions: VN = V × 298 × P / (Tm × 760). Sulphur dioxide (stack): C = 0.032 × (Vₛ − V_b) × N × (Vₛₒₗ / Vₐ) × 1000 / VN. Sulphur dioxide (stack): ppm = C × 24.45 / 64.066. Here T is the sampling time (min), Q is the flow rate (L/min), Tm is the average dry gas meter temperature (absolute) (K), Pa is the atmospheric pressure (mmHg), Pv is the vacuum at the meter (mmHg), Vₛ is the barium perchlorate used for sample (ml), V_b is the barium perchlorate used for blank (ml), N is the normality of barium perchlorate (N), Vₛₒₗ is the total volume of absorbing solution (ml), Vₐ is the aliquot titrated (ml). The result is in mg/Nm³.
What unit is sulphur dioxide (stack) reported in?
Sulphur dioxide (stack) is reported in mg/Nm³, to 1 decimal place.
Which standard does this sulphur dioxide (stack) calculation follow?
It follows the calculation in IS 11255 (Part 2). Check it against the current edition of the standard and your lab’s SOP before reporting.
Can you show a worked example?
With sampling time = 60 min, flow rate = 1 L/min, average dry gas meter temperature (absolute) = 303 K, atmospheric pressure = 712 mmHg, vacuum at the meter = 25 mmHg, barium perchlorate used for sample = 4.6 ml, barium perchlorate used for blank = 0.1 ml, normality of barium perchlorate = 0.01 N, total volume of absorbing solution = 100 ml, aliquot titrated = 20 ml, the result is sulphur dioxide (stack) = 135.0 mg/Nm³ and sulphur dioxide (stack) = 51.5 ppm.
What mistakes should I look out for?
The sample titre is less than the blank, so the result would be negative.
Is this sulphur dioxide (stack) calculator free?
Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.
Related calculators
Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.