Skip to content
SO₂

Sulphur dioxide (stack)

Barium perchlorate titrationResult in mg/Nm³IS 11255 (Part 2)

Pink → blue-violet at the endpoint (thorin)

Formulas, in order
Volume of gas sampled (meter) · m³
V =T×Q1000
Absolute meter pressure · mmHg
P =Pa−Pv
Volume at normal conditions · Nm³
VN =V×298×P(Tm×760)
Sulphur dioxide (stack) · mg/Nm³
C =0.032×(Vₛ−V_b)×N×(VₛₒₗVₐ)×1000VN
Sulphur dioxide (stack) · ppm
ppm =C×24.4564.066

Your readings

10 of 10 filled

Example values shown.

min
L/min
K
mmHg
mmHg
ml
ml
N
ml
ml
Milliequivalent weight of SO₂Constant · fixed by the method0.032g/meq
Molecular weight of SO₂Constant · fixed by the method64.066🔒
Molar volume at 25 °C and 1 atmConstant · fixed by the method24.45L
Sulphur dioxide (stack)Calculated live as you type
135.0 mg/Nm³mg/Nm³
  • Sulphur dioxide (stack)51.5 ppm
Worked out with the formula above.

Calculations you finish this week are counted here, on this device only.

How sulphur dioxide (stack) is calculated

Free sulphur dioxide (stack) calculator (barium perchlorate titration method), following IS 11255 (Part 2). Enter 10 readings to get sulphur dioxide (stack) in mg/Nm³, with the formula filled in step by step.

  1. Volume of gas sampled (meter) · m³

    V = T × Q / 1000

  2. Absolute meter pressure · mmHg

    P = Pa − Pv

  3. Volume at normal conditions · Nm³

    VN = V × 298 × P / (Tm × 760)

  4. Sulphur dioxide (stack) · mg/Nm³

    C = 0.032 × (Vₛ − V_b) × N × (Vₛₒₗ / Vₐ) × 1000 / VN

  5. Sulphur dioxide (stack) · ppm

    ppm = C × 24.45 / 64.066

What you need

SymbolReadingUnitNotes
TSampling timeminusually 5–240 min
QFlow rateL/minusually 0.1–10 L/min
TmAverage dry gas meter temperature (absolute)Kusually 273–330 K
PaAtmospheric pressuremmHgusually 600–800 mmHg
PvVacuum at the metermmHgusually 0–200 mmHg
VₛBarium perchlorate used for samplemlusually 0–50 ml
V_bBarium perchlorate used for blankmlusually 0–2 ml
NNormality of barium perchlorateNusually 0.001–0.1 N
VₛₒₗTotal volume of absorbing solutionmlusually 10–500 ml
VₐAliquot titratedmlusually 1–100 ml

Fixed values in the formula

SymbolConstantValue
0.032Milliequivalent weight of SO₂0.032 g/meq
64.066Molecular weight of SO₂64.066
24.45Molar volume at 25 °C and 1 atm24.45 L

Worked example

Readings:

  • Sampling time: T = 60 min
  • Flow rate: Q = 1 L/min
  • Average dry gas meter temperature (absolute): Tm = 303 K
  • Atmospheric pressure: Pa = 712 mmHg
  • Vacuum at the meter: Pv = 25 mmHg
  • Barium perchlorate used for sample: Vₛ = 4.6 ml
  • Barium perchlorate used for blank: V_b = 0.1 ml
  • Normality of barium perchlorate: N = 0.01 N
  • Total volume of absorbing solution: Vₛₒₗ = 100 ml
  • Aliquot titrated: Vₐ = 20 ml
  1. Volume of gas sampled (meter)

    V = 60 × 1 / 1000 = 0.0600 m³

  2. Absolute meter pressure

    P = 712 − 25 = 687.0 mmHg

  3. Volume at normal conditions

    VN = 0.0600 × 298 × 687.0 / (303 × 760) = 0.0533 Nm³

  4. Sulphur dioxide (stack)

    C = 0.032 × (4.6 − 0.1) × 0.01 × (100 / 20) × 1000 / 0.0533 = 135.0 mg/Nm³

  5. Sulphur dioxide (stack)

    ppm = 135.0 × 24.45 / 64.066 = 51.5 ppm

Result: Sulphur dioxide (stack) 135.0 mg/Nm³; sulphur dioxide (stack) 51.5 ppm.

Checks and units

  • The sample titre is less than the blank, so the result would be negative.

Questions

How do you calculate sulphur dioxide (stack) by the barium perchlorate titration method?

Work through 5 steps in order. Volume of gas sampled (meter): V = T × Q / 1000. Absolute meter pressure: P = Pa − Pv. Volume at normal conditions: VN = V × 298 × P / (Tm × 760). Sulphur dioxide (stack): C = 0.032 × (Vₛ − V_b) × N × (Vₛₒₗ / Vₐ) × 1000 / VN. Sulphur dioxide (stack): ppm = C × 24.45 / 64.066. Here T is the sampling time (min), Q is the flow rate (L/min), Tm is the average dry gas meter temperature (absolute) (K), Pa is the atmospheric pressure (mmHg), Pv is the vacuum at the meter (mmHg), Vₛ is the barium perchlorate used for sample (ml), V_b is the barium perchlorate used for blank (ml), N is the normality of barium perchlorate (N), Vₛₒₗ is the total volume of absorbing solution (ml), Vₐ is the aliquot titrated (ml). The result is in mg/Nm³.

What unit is sulphur dioxide (stack) reported in?

Sulphur dioxide (stack) is reported in mg/Nm³, to 1 decimal place.

Which standard does this sulphur dioxide (stack) calculation follow?

It follows the calculation in IS 11255 (Part 2). Check it against the current edition of the standard and your lab’s SOP before reporting.

Can you show a worked example?

With sampling time = 60 min, flow rate = 1 L/min, average dry gas meter temperature (absolute) = 303 K, atmospheric pressure = 712 mmHg, vacuum at the meter = 25 mmHg, barium perchlorate used for sample = 4.6 ml, barium perchlorate used for blank = 0.1 ml, normality of barium perchlorate = 0.01 N, total volume of absorbing solution = 100 ml, aliquot titrated = 20 ml, the result is sulphur dioxide (stack) = 135.0 mg/Nm³ and sulphur dioxide (stack) = 51.5 ppm.

What mistakes should I look out for?

The sample titre is less than the blank, so the result would be negative.

Is this sulphur dioxide (stack) calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Related calculators

All stack emissions calculators →

Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.

Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.