How particulate matter (stack) is calculated
Free particulate matter (stack) calculator (Isokinetic, gravimetric method), following IS 11255 (Part 1). Enter 6 readings to get particulate matter in mg/Nm³, with the formula filled in step by step.
Volume sampled at normal conditions · Nm³
Vn = Vm × (298 / Tg) × (Pa − Pv) / 760
Particulate matter · mg/Nm³
PM = (W2 − W1) × 1000 / Vn
What you need
| Symbol | Reading | Unit | Notes |
|---|---|---|---|
| Vm | Volume of flue gas sampled (meter) | m³ | usually 0.1–10 m³ |
| Tg | Average gas meter temperature (absolute) | K | usually 273–330 K |
| Pa | Atmospheric pressure | mmHg | usually 600–800 mmHg |
| Pv | Average vacuum at the meter | mmHg | usually 0–200 mmHg |
| W1 | Initial weight of thimble | g | usually 0–50 g |
| W2 | Final weight of thimble with dust | g | usually 0–50 g |
Worked example
Readings:
- Volume of flue gas sampled (meter): Vm = 1.2 m³
- Average gas meter temperature (absolute): Tg = 305 K
- Atmospheric pressure: Pa = 712 mmHg
- Average vacuum at the meter: Pv = 38 mmHg
- Initial weight of thimble: W1 = 4.152 g
- Final weight of thimble with dust: W2 = 4.203 g
Volume sampled at normal conditions
Vn = 1.2 × (298 / 305) × (712 − 38) / 760 = 1.0398 Nm³
Particulate matter
PM = (4.203 − 4.152) × 1000 / 1.0398 = 49.0 mg/Nm³
Result: Particulate matter 49.0 mg/Nm³.
Checks and units
- Typical values: Typical limit for boilers: 150 mg/Nm³
- The thimble weighs less after sampling.
- The vacuum can't be more than atmospheric pressure.
Questions
How do you calculate particulate matter (stack) by the Isokinetic, gravimetric method?
Work through 2 steps in order. Volume sampled at normal conditions: Vn = Vm × (298 / Tg) × (Pa − Pv) / 760. Particulate matter: PM = (W2 − W1) × 1000 / Vn. Here Vm is the volume of flue gas sampled (meter) (m³), Tg is the average gas meter temperature (absolute) (K), Pa is the atmospheric pressure (mmHg), Pv is the average vacuum at the meter (mmHg), W1 is the initial weight of thimble (g), W2 is the final weight of thimble with dust (g). The result is in mg/Nm³.
What unit is particulate matter (stack) reported in?
Particulate matter is reported in mg/Nm³, to 1 decimal place.
Which standard does this particulate matter (stack) calculation follow?
It follows the calculation in IS 11255 (Part 1). Check it against the current edition of the standard and your lab’s SOP before reporting.
Can you show a worked example?
With volume of flue gas sampled (meter) = 1.2 m³, average gas meter temperature (absolute) = 305 K, atmospheric pressure = 712 mmHg, average vacuum at the meter = 38 mmHg, initial weight of thimble = 4.152 g, final weight of thimble with dust = 4.203 g, the result is particulate matter = 49.0 mg/Nm³.
What is a typical particulate matter (stack) value?
Typical limit for boilers: 150 mg/Nm³
What mistakes should I look out for?
The thimble weighs less after sampling. The vacuum can't be more than atmospheric pressure.
Is this particulate matter (stack) calculator free?
Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.
Related calculators
Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.