Skip to content
100%PM

Particulate matter (stack)

Isokinetic, gravimetricResult in mg/Nm³IS 11255 (Part 1)

Dust caught in a thimble, weighed

Formulas, in order
Volume sampled at normal conditions · Nm³
Vn =Vm×(298Tg)×(Pa−Pv)760
Particulate matter · mg/Nm³
PM =(W2−W1)×1000Vn

Your readings

6 of 6 filled

Example values shown.

m³
K
mmHg
mmHg
g
g
Particulate matterCalculated live as you type
49.0 mg/Nm³mg/Nm³
Within the usual range. Typical limit for boilers: 150 mg/Nm³.

Calculations you finish this week are counted here, on this device only.

How particulate matter (stack) is calculated

Free particulate matter (stack) calculator (Isokinetic, gravimetric method), following IS 11255 (Part 1). Enter 6 readings to get particulate matter in mg/Nm³, with the formula filled in step by step.

  1. Volume sampled at normal conditions · Nm³

    Vn = Vm × (298 / Tg) × (Pa − Pv) / 760

  2. Particulate matter · mg/Nm³

    PM = (W2 − W1) × 1000 / Vn

What you need

SymbolReadingUnitNotes
VmVolume of flue gas sampled (meter)m³usually 0.1–10 m³
TgAverage gas meter temperature (absolute)Kusually 273–330 K
PaAtmospheric pressuremmHgusually 600–800 mmHg
PvAverage vacuum at the metermmHgusually 0–200 mmHg
W1Initial weight of thimblegusually 0–50 g
W2Final weight of thimble with dustgusually 0–50 g

Worked example

Readings:

  • Volume of flue gas sampled (meter): Vm = 1.2 m³
  • Average gas meter temperature (absolute): Tg = 305 K
  • Atmospheric pressure: Pa = 712 mmHg
  • Average vacuum at the meter: Pv = 38 mmHg
  • Initial weight of thimble: W1 = 4.152 g
  • Final weight of thimble with dust: W2 = 4.203 g
  1. Volume sampled at normal conditions

    Vn = 1.2 × (298 / 305) × (712 − 38) / 760 = 1.0398 Nm³

  2. Particulate matter

    PM = (4.203 − 4.152) × 1000 / 1.0398 = 49.0 mg/Nm³

Result: Particulate matter 49.0 mg/Nm³.

Checks and units

  • Typical values: Typical limit for boilers: 150 mg/Nm³
  • The thimble weighs less after sampling.
  • The vacuum can't be more than atmospheric pressure.

Questions

How do you calculate particulate matter (stack) by the Isokinetic, gravimetric method?

Work through 2 steps in order. Volume sampled at normal conditions: Vn = Vm × (298 / Tg) × (Pa − Pv) / 760. Particulate matter: PM = (W2 − W1) × 1000 / Vn. Here Vm is the volume of flue gas sampled (meter) (m³), Tg is the average gas meter temperature (absolute) (K), Pa is the atmospheric pressure (mmHg), Pv is the average vacuum at the meter (mmHg), W1 is the initial weight of thimble (g), W2 is the final weight of thimble with dust (g). The result is in mg/Nm³.

What unit is particulate matter (stack) reported in?

Particulate matter is reported in mg/Nm³, to 1 decimal place.

Which standard does this particulate matter (stack) calculation follow?

It follows the calculation in IS 11255 (Part 1). Check it against the current edition of the standard and your lab’s SOP before reporting.

Can you show a worked example?

With volume of flue gas sampled (meter) = 1.2 m³, average gas meter temperature (absolute) = 305 K, atmospheric pressure = 712 mmHg, average vacuum at the meter = 38 mmHg, initial weight of thimble = 4.152 g, final weight of thimble with dust = 4.203 g, the result is particulate matter = 49.0 mg/Nm³.

What is a typical particulate matter (stack) value?

Typical limit for boilers: 150 mg/Nm³

What mistakes should I look out for?

The thimble weighs less after sampling. The vacuum can't be more than atmospheric pressure.

Is this particulate matter (stack) calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Related calculators

All stack emissions calculators →

Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.

Run every calculation inside your LIMS