How ozone is calculated
Free ozone calculator (colorimetric method), following IS 5182 (Part 9). Enter 5 readings to get ozone in µg/m³, with the formula filled in step by step.
Volume of air sampled · m³
Va = Q × t / 1000
Ozone · µg/m³
O₃ = (Aₛ − A_b) × CF × 1.962 / Va
What you need
| Symbol | Reading | Unit | Notes |
|---|---|---|---|
| CF | Calibration factor | µg per Abs | usually 0.1–200 µg per Abs |
| Q | Average flow rate | L/min | usually 0.1–5 L/min |
| t | Sampling time | min | usually 10–1440 min |
| Aₛ | Absorbance of sample | Abs | usually 0–2 Abs |
| A_b | Absorbance of blank | Abs | usually 0–0.2 Abs |
Fixed values in the formula
| Symbol | Constant | Value |
|---|---|---|
| 1.962 | Conversion factor | 1.962 |
Worked example
Readings:
- Calibration factor: CF = 42 µg per Abs
- Average flow rate: Q = 1 L/min
- Sampling time: t = 480 min
- Absorbance of sample: Aₛ = 0.118 Abs
- Absorbance of blank: A_b = 0.012 Abs
Volume of air sampled
Va = 1 × 480 / 1000 = 0.4800 m³
Ozone
O₃ = (0.118 − 0.012) × 42 × 1.962 / 0.4800 = 18.2 µg/m³
Result: Ozone 18.2 µg/m³.
Checks and units
- Typical values: 8-hour standard (NAAQS): 100 µg/m³
- The sample absorbance is lower than the blank, so the result would be negative.
Questions
How do you calculate ozone by the colorimetric method?
Work through 2 steps in order. Volume of air sampled: Va = Q × t / 1000. Ozone: O₃ = (Aₛ − A_b) × CF × 1.962 / Va. Here CF is the calibration factor (µg per Abs), Q is the average flow rate (L/min), t is the sampling time (min), Aₛ is the absorbance of sample (Abs), A_b is the absorbance of blank (Abs). The result is in µg/m³.
What unit is ozone reported in?
Ozone is reported in µg/m³, to 1 decimal place.
Which standard does this ozone calculation follow?
It follows the calculation in IS 5182 (Part 9). Check it against the current edition of the standard and your lab’s SOP before reporting.
Can you show a worked example?
With calibration factor = 42 µg per Abs, average flow rate = 1 L/min, sampling time = 480 min, absorbance of sample = 0.118 Abs, absorbance of blank = 0.012 Abs, the result is ozone = 18.2 µg/m³.
What is a typical ozone value?
8-hour standard (NAAQS): 100 µg/m³
What mistakes should I look out for?
The sample absorbance is lower than the blank, so the result would be negative.
Is this ozone calculator free?
Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.