Skip to content
560 nmSO₂

Sulphur dioxide

Improved West and Gaeke (by shift)Result in µg/m³IS 5182 (Part 2)

Turns red-purple (pararosaniline) · read at 560 nm

Formulas, in order
Volume of air sampled · L · each shift
V =Q×t
Volume at 25 °C and 760 mmHg · L · each shift
Vr =V×(P760)×298(T+273)
SO₂ for the shift · µg/m³ · each shift
C =(Aₛ−A_b)×G.F×1000×DFVr
Average sulphur dioxide · µg/m³
SO₂ =avg(C)

Your readings

4 of 4 filled

Example values shown.

mmHg
µg per Abs
ShifttSampling timeminQFlow rateL/minTTemperature°CAₛAbsorbance of sampleAbsA_bAbsorbance of blankAbsVVolume of air sampledLVrVolume at 25 °C and 760 mmHgLCSO₂ for the shiftµg/m³
Shift 1240222.64.6
Shift 2240221.135.6
Shift 3240220.44.3
Shift 4240223.343.8
Shift 5240224.843.3
Shift 6240225.63.5
Average sulphur dioxideCalculated live as you type
4.2 µg/m³µg/m³
Within the usual range. 24-hour standard (NAAQS): 80 µg/m³.

Calculations you finish this week are counted here, on this device only.

How sulphur dioxide is calculated

Free sulphur dioxide calculator (improved West and Gaeke (by shift) method), following IS 5182 (Part 2). Enter 8 readings to get average sulphur dioxide in µg/m³, with the formula filled in step by step.

  1. Volume of air sampled · L · for each shift

    V = Q × t

  2. Volume at 25 °C and 760 mmHg · L · for each shift

    Vr = V × (P / 760) × 298 / (T + 273)

  3. SO₂ for the shift · µg/m³ · for each shift

    C = (Aₛ − A_b) × G.F × 1000 × DF / Vr

  4. Average sulphur dioxide · µg/m³

    SO₂ = avg(C)

What you need

SymbolReadingUnitNotes
PAtmospheric pressuremmHgusually 600–800 mmHg
G.FGraph factorµg per Absusually 0.5–100 µg per Abs
DFDilution factor—usually 1–100
tSampling timeminone per shift; usually 10–600 min
QFlow rateL/minone per shift; usually 0.1–5 L/min
TTemperature°Cone per shift; usually -10–55 °C
AₛAbsorbance of sampleAbsone per shift; usually 0–2 Abs
A_bAbsorbance of blankAbsone per shift; usually 0–0.2 Abs

Worked example

Readings:

  • Atmospheric pressure: P = 712 mmHg
  • Graph factor: G.F = 22.5 µg per Abs
  • Dilution factor: DF = 1
  • Sampling time: t = 240, 240, 240, 240, 240, 240 min
  • Flow rate: Q = 1, 1, 1, 1, 1, 1 L/min
  • Temperature: T = 28, 30, 31, 27, 25, 24 °C
  • Absorbance of sample: Aₛ = 0.052, 0.061, 0.048, 0.044, 0.039, 0.041 Abs
  • Absorbance of blank: A_b = 0.006, 0.006, 0.006, 0.006, 0.006, 0.006 Abs
  1. Volume of air sampled

    V = 240.0, 240.0, 240.0, 240.0, 240.0, 240.0 L

  2. Volume at 25 °C and 760 mmHg

    Vr = 222.60, 221.13, 220.40, 223.34, 224.84, 225.60 L

  3. SO₂ for the shift

    C = 4.6, 5.6, 4.3, 3.8, 3.3, 3.5 µg/m³

  4. Average sulphur dioxide

    SO₂ = avg(4.6, 5.6, 4.3, 3.8, 3.3, 3.5) = 4.2 µg/m³

Result: Average sulphur dioxide 4.2 µg/m³.

Checks and units

  • Typical values: 24-hour standard (NAAQS): 80 µg/m³
  • Each shift needs a sampling time and flow rate.

Questions

How do you calculate sulphur dioxide by the improved West and Gaeke (by shift) method?

Work through 4 steps in order. Volume of air sampled: V = Q × t. Volume at 25 °C and 760 mmHg: Vr = V × (P / 760) × 298 / (T + 273). SO₂ for the shift: C = (Aₛ − A_b) × G.F × 1000 × DF / Vr. Average sulphur dioxide: SO₂ = avg(C). Here P is the atmospheric pressure (mmHg), G.F is the graph factor (µg per Abs), DF is the dilution factor. The result is in µg/m³.

What unit is sulphur dioxide reported in?

Average sulphur dioxide is reported in µg/m³, to 1 decimal place.

Which standard does this sulphur dioxide calculation follow?

It follows the calculation in IS 5182 (Part 2). Check it against the current edition of the standard and your lab’s SOP before reporting.

Can you show a worked example?

With atmospheric pressure = 712 mmHg, graph factor = 22.5 µg per Abs, dilution factor = 1, sampling time = 240, 240, 240, 240, 240, 240 min, flow rate = 1, 1, 1, 1, 1, 1 L/min, temperature = 28, 30, 31, 27, 25, 24 °C, absorbance of sample = 0.052, 0.061, 0.048, 0.044, 0.039, 0.041 Abs, absorbance of blank = 0.006, 0.006, 0.006, 0.006, 0.006, 0.006 Abs, the result is average sulphur dioxide = 4.2 µg/m³.

What is a typical sulphur dioxide value?

24-hour standard (NAAQS): 80 µg/m³

What mistakes should I look out for?

Each shift needs a sampling time and flow rate.

Is this sulphur dioxide calculator free?

Yes. It’s free with no sign-up. The calculation runs in your browser and nothing you type is sent to NovaLIMS.

Related calculators

All ambient air calculators →

Check results against your own method and SOP before reporting. Found an error? Tell us and we’ll check it.

Run every calculation inside your LIMS

NovaLIMS puts these calculators right beside each sample’s parameters, for every analyst in the lab.